The U range in voltage section is not chosen correctly: if the opening time is slightly prolonged (in idle run), all injectors “fall” below minimum voltage of 130V (actual minimum voltage is a bit different number…)ģ bottom lines are for long-term trims of injectors, in mJ. Readings of energy and voltage can be used to discover damages for piezoelectric elements (micro-flaws, power leakage to injector’s body. Shows time for one cycle (in case of multi-point injection) – it’s not clear, which exactly ī) next 3 lines – relative correction of injectors opening time (factory grouping correction and additional individual correction).Ī) 3 lines – amount of energy, which is conducted to each injector ī) next 3 lines – peak voltage while opening the injector. Pressing F1, we see the following picture:Ī) 3 lines on top – opening time of injectors. More interesting is Injector menu (Shift + F6): Rough run menu still has the wide-band Lambda probe section with indications in volts (not in Lambda value). NOx sensor menu moved to separate sub-menu, why – it’s not clear. The +/-700 mg/stk range for offset long-term trims has stayed the same, so – no use for this bar. Now there are bars with total correction: integrator + long-term trim (in %): no need to calculate by myself anymore Menu for short and long-term trims is upgraded: Today I got 2.023 loader and decided to test it. Till now I was using one of the newest (stable) INPA versions – 5.0.6, which was using 1.001 loader for MSD80 diagnostics.